ultraLink processor module with 8/8 relay outputs/inputs. DIN-rail mount
  • Hosts one network communication card
  • Expansion port for up to 8 Ultralink expansion modules
  • USB configuration port
  • 8 relay outputs
  • 8 dry-contact inputs
View all

Alternative products

At a glance

Ultralink I/O modules are used to receive and/or transmit alarm information as part of an integrated security system.
Applications include:
-Converting FlexZone sensor alamr collected over the Silver Network to relays or open-collector outputs for input to a 3rd party Secuity Management System.
-Collecting auxiliary sensor alarms with dry-contact inpiuts for display with a Management system.
The Ultralink I/O module connects to the SIlver Network via a communication card. Up to 8 Ultralink expansion modules can be attached to one UltraLink module (DF432). Configuring the mods of operation of the relay ouputs, open-collector outputs and dry-contact inputs is done with the UCM software. The UCM can be connected to the Ultralink modules either by a direct USB connector to the I/O processor or by an IP connection via the Network manager Software.

Details

  • Hosts one network communication card
  • Expansion port for up to 8 Ultralink expansion modules
  • USB configuration port
  • 8 relay outputs
  • 8 dry-contact inputs
  • Supplies power to connected modules
  • Modular system comprised of processor module, relay module, open-collector output module & dry-contact input module

Technical specifications

General
Category
FlexZone
Product type
FlexZone Control unit
Electrical
Operating voltage
12 to 48 VDC
Physical
Physical dimensions
160 x 118 mm
Environmental
Relative humidity
0 to 95%, non condensing
Environment
Indoor