Skip to main content

SB2100-N

AIR two-beam detector 100 m with integrated Heater and Alignment tool
  • 2 active infrared (AIR) beams
  • Outdoor range 100 m
  • 4 selectable channels
  • On board regulated heater
  • Disqualification
View all

At a glance

The new SB active infrared beams' series includes two-beam and four-beam detectors, which generate an alarm when 1 or 2 beams are interrupted, ignoring birds, small animals, dead leaves, etc.

They consist of two identical detector modules equipped with detector cells integrating both transmission and reception functions. These modules are installed facing each other over the distance to be protected providing a non-physical invisible detection zone.
Detectors are based on a system of pulsed infrared beams, and operate on four user-selectable frequencies (channels), which allow avoiding any risk of interference between detectors.
Thanks to an integrated alignment tool, which provide visual and audible signal, beams are much quicker and easier to align.
Heater is also integrated on the beams.
Thanks to modules interconnectivity option (offered for SB250-N, SB2100-N, SB450-N and SB4100), there are NO detection gaps between modules.

Details

  • 2 active infrared (AIR) beams
  • Outdoor range 100 m
  • 4 selectable channels
  • On board regulated heater
  • Disqualification
  • Integrated alignment tool (visual/audio)
  • NO gaps in detection between modules thanks to interdetection option
  • Receiver and Transceiver in one module
  • Modular pillar for 180° & 360° view
  • Very strong pillars up to 3 m

Technical specifications

General
Accessory group
Perimeter / Outdoor
Type
Test tool
Electrical
Operating voltage
10 to 15 V
Current consumption
Beam: 47 mA @ 12 VDC (1 module)
Heater: 80 mA @ 12 VDC (1 module)
Physical
Physical dimensions
84 x 280 x 113 mm (W x H x D)
Net weight
0.9 kg
Environmental
Operating temperature
-25 to +55°C (with heater)
IP rating
IP44
Detection
Max. range indoors 250 m
Max. range outdoors 100 m
Intrusion alarm response time 50 to 800 ms
Disqualification alarm response time 60 s non-adjustable
Typical duration of intrusion alarm Duration of cell interruption, with a minimum of 4 s
Number of beams
2
Beams interruption switching mode
All beams
Heater power supply
10 to 15 VAC/VDC
Output relays
Alarm (NC = alarm off)
Tamper (NC = alarm off)
Disqualification (NO = alarm off)
Output rating (each)
30 VDC, 500 mA
Integrated alignment tool
Optical viewfinder system, LED, buzzer indicating quality of the received signal
Cell direction adjustability
Vertically +/- 10°
Module direction adjustability
Horizontally +/- 90°

Downloads

All downloads

Datasheet

Certificates

If available, the downloads of the Certificates, Software & Firmware and Media are displayed in their default language.